Skip to main content
Version: v2.18.x

Error Message Codes

Error Message Codes

The following error message codes may appear on Zowe Launcher SYSPRINT. Use the following message code references and the corresponding reasons and actions to help troubleshoot issues.

Zowe Launcher informational messages

ZWEL0001I

component %s started

Reason:

Component <component-name> started.

Action:

No action required.

ZWEL0002I

component %s stopped

Reason:

Component <component-name> stopped.

Action:

No action required.

ZWEL0003I

new component initialized %s, restart_cnt=%d, min_uptime=%d seconds, share_as=%s

Reason:

Component <component-name> initialized.

  • restart_cnt - Number of attempts to restart the component in case of failure
  • min_uptime - Minimum uptime that the component can be considered as successfully started
  • share_as - One of <yes|no|must> which indicates whether child processes of the component start in the same address space. See documentation for _BPX_SHAREAS for details.

Action:

No action required.

ZWEL0004I

component %s(%d) terminated, status = %d

Reason:

Component <component-name>(<pid>) terminated with status <code>.

Action:

No action required.

ZWEL0005I

next attempt to restart component %s in %d seconds

Reason:

Component failure detected.

Action:

No action required. The component <component-name> will be restarted in <n> seconds.

Zowe Launcher error messages

ZWEL0030E

failed to prepare Zowe instance

Reason:

Failed to prepare the Zowe high availability (HA) instance.

Action:

Check previous messages in the Zowe Launcher SYSPRINT to find the reason and correct it.

ZWEL0038E

failed to restart component %s, max retries reached

Reason:

Maximum retries reached for restarting component <component-name>.

Action:

Check <component-name> configuration and correct the maximum restart count via configuration attribute restartIntervals if needed, then restart the component by using z/OS MODIFY command F ZWESLSTC,APPL=STOP(<component-name>)

ZWEL0040E

failed to start component %s

Reason:

Failed to start component <component-name>.

Action:

Check <component-name> configuration and correct if needed, then either 1) start the component manually by using z/OS MODIFY command F ZWESLSTC,APPL=STOP(<component-name>) or 2) restart the entire HA instance

ZWEL0047E

failed to parse zowe.yaml - %s

Reason:

Failed to parse Zowe configuration file.

Action:

Validate the format of Zowe configuration file. It should be a valid YAML file following specifications defined in https://yaml.org/.

ZWEL0073E

Launcher Could not load schemas, status=5

Reason:

The Zowe Launcher was able to locate the runtime directory, but unable to find the /schemas directory.

Action:

Locate the runtimeDirectory from the zowe.yaml variable runtimeDirectory: "<PATH_TO_RUNTIME>".

Check that there is a <PATH_TO_RUNTIME>/schemas directory. This should contain four .json files shown below.

manifest-schema.json
server-common-json
trivial-component-schema.json
zowe-yaml-schema.json

On ocassion the error occurs because the runtimeDirectory is pointing to a valid directory, but one which doesn't contain a valid Zowe runtime environment is one of the first failures during a Zowe launch.